Compressed Gas: Storage and Handling

Follow basic safe storage and handling practices for compressed gases at UT Dallas.

These basic storage and handling requirements apply to all compressed gases and can be found in the Chemical Hygiene Plan as well as within this webpage.

Requirements for researchers and/or responsible parties

At UT Dallas researchers working with compressed gases must follow an approved Standard Operating Procedure (SOP) found in the Chemical Registration Form. The SOP must be preapproved by the principal investigator prior to beginning any work with this material and any gas brought into campus must be approved by the Chemical Hygiene Officer.

Information on this webpage is supplementary and is not intended to replace the approved SOP.

Basic Storage Requirements

Follow the requirements for storing compressed gas cylinders:

  • Select a cool, dry and well-ventilated area. Cool areas minimize pressure increases that can result from heat or direct sunlight. Dryness deters rust and corrosion. Ventilation is essential in case of leaks.
  • Never store compressed gas cylinders (with the exception of compressed air) in environmental rooms (i.e., refrigerated cold rooms or warm rooms). These rooms are not well-ventilated and could pose a serious safety concern should a cylinder fail.
  • Do not store cylinders next to doors or in corridors where they could possibly obstruct emergency exits from the building.
  • Separate oxidizers or other non-compatibles (e.g., oxygen) from flammables by at least 20 feet, or by a non-combustible wall.
  • Properly label the cylinders and the storage area. Cylinders need to be identified as full, in-use or empty.
  • Arrange storage facilities to permit inventory rotation, using cylinders in order as received from the supplier.
  • Store full and empty cylinders separately to avoid confusion. Serious suck-back can occur when an empty cylinder is attached to a pressurized system.
  • Designate an area to store empty cylinders for return to the supplier. An area on or adjacent to your building’s loading dock is suitable.

For guidance on how to return empty cylinders, contact Risk & Safety.

Keep Inventories Lean

Some compressed gas cylinders are rented or leased, rather than purchased. Some vendors charge a reconditioning fee on each cylinder that is not returned within two years. This fee may be significant in relation to the actual cost of the gas.

  • Review your cylinder inventory monthly.
  • Return empty and unwanted cylinders to the vendor to eliminate potential hazards, save on cylinder rental bills and avoid possible reconditioning fees.
  • Do not keep non-corrosive gases longer than 10 years from the last hydrostatic test date (usually stamped just below the neck of the cylinder) unless otherwise regulated.
  • Never store corrosives longer than six months (examples: ammonia, hydrogen chloride, chlorine and methylamine). Cylinders containing corrosives degrade over time.
  • Return all cylinders that appear unsafe or show signs of corrosion, dents, dings, pitting, bulging, etc.

If cylinders are unable to be returned to the manufacturer, our Hazardous Waste Team will dispose of the cylinder(s). When our team disposes the cylinders, you may incur a charge. If it best to coordinate a pick up with the vendor to ensure that you are not charged for disposal.

Restrain Compressed Gas Cylinders

Compressed gas cylinders in UT Dallas facilities must be secured at all times, whether empty or full and must be labeled appropriately.

Store cylinders upright and secure them to a substantial, fixed surface with upper and lower restraints made of non-combustible material, preferably chain and Unistrut®.

How to effectively restrain cylinders:

  • Restraints should be tight.
  • Position the upper restraint no less than one foot from the shoulder of the cylinder. Position the lower restraint no less than one foot from the floor.
  • C-clamps or bench mounting brackets are not allowed for permanent storage.
  • Preferably restrain cylinders individually. If unavoidable, only restrain three or fewer cylinders per restraint. When restraining multiple cylinders, keep them secure and interlocked into a compact group with the sides and bottoms of all cylinders fully contained.
  • Cap cylinders when not in use.

Operational Requirements

Read the Safety Data Sheet and label information before starting work with a new material.

Follow these operational requirements:

  • Label both the cylinder and gas line with the name of the gas. Do not depend on color codes. If your gas requires a detection system, the gas cabinet and detector must be labeled with the name of the gas.
  • Work in a well-ventilated area when using compressed gases.
  • Use the correct regulator. Ensure each gas in use has its own dedicated regulator. Never use adapters.
  • Never permit a flame or spark to come in contact with any part of a compressed gas cylinder.
  • Install flashback protectors on cylinders of flammable gases, such as oxy-acetylene torch units.
  • Use a trap or suitable check valve when discharging gas into a liquid to prevent liquid from getting back into the cylinder or regulator.

In Case of Leaks

In case of cylinder leaks that cannot be stopped by tightening the valve gland or packing nut, do the following:

For Hazardous Gases

  1. Leave the room, closing the door behind you.
  2. Secure the room to prevent entry.
  3. Sound the fire alarm.
  4. Call for emergency assistance:
    • UT Dallas Police Department (972-883-2222) or dial 9-1-1,
    • Tell the dispatcher the name and location of the gas.

For Non-hazardous Gases

Close the leaking valve. Is it still leaking?

  • Yes – remove yourself from the room, block off entry and notify Risk & Safety.
  • No – Contact vendor for removal.

Transporting Gas Cylinders

Follow these best practices for transporting compressed gas cylinders:

Gas cylinders can only be transported within the building they were delivered. It is against DOT regulations to transport gas cylinders across public streets within the UTD campus. If you require your cylinder(s) to be moved from one building to another, contact your vendor for assistance. You will incur a fee for this service.

  • Leave the valve protection cap on until the cylinder is secured against a wall or bench or placed in a cylinder stand, and is ready for use.
  • Use a hand truck or other suitable device to transport cylinders, even for short distances. Secure the cylinder to the hand truck with a chain or strap.
  • Do not roll, drag or slide containers.
  • Do not lift cylinders by cylinder caps.
  • Before returning empty cylinders to the supplier:
  • Close the valve. Leave some positive pressure in the cylinder.
  • Replace original valve outlets and protective caps shipped with the cylinder.
  • Mark or label the cylinder “empty” and store it in a designated area for the supplier.

Important: Move unattended cylinders to a secure location as soon as possible.

Flammable, Oxidizing and Corrosive Gases

In addition to standard storage and operational requirements listed above, employ special precautions for cylinders containing flammable, oxidizing or corrosive gases (empty or full). See the Toxic and Hazardous Gas Classifications Chart for detailed information on all gases.

Flammable Gases

Storage

  • Separate from cylinders containing oxidizing gases by a minimum distance of 20 feet or by a noncombustible partition extending not less than 18 inches above and to the sides of the stored material with two hour fire protection.
  • Flammable gases can be stored/used in the open lab if they are stored/used appropriately. If they are stored/used in an approved gas cabinet, the gas cabinet must be equipped with fire sprinklers.
  • Never store flammable gases near ignition or heat sources, electrical panels, unprotected electrical connections or in corridors.
  • Keep quantities to a minimum. There are strict quantity limits as determined by Fire Code. Contact the Chemical Hygiene Officer for your MAQ.
  • There may be circumstances where using a pure flammable gas may pose unacceptable risks. It may be necessary to purchase a reduced concentration mixture (e.g., 1% hydrogen and 99% argon).

If you need large volumes (more than one large cylinder), contact the Chemical Hygiene Officer.

Operations

  • Use flow restrictors to prevent a sudden large unexpected release.
  • Detection systems may be required. Contact the Chemical Hygiene Officer for a review.

Inert/Flammable Gas Mixtures

Nitrogen/Hydrogen – Any mixture greater than 5% hydrogen balance nitrogen is flammable.

Argon/Hydrogen – Any mixture greater than 3% hydrogen balance argon is flammable.

Additional Information on Hydrogen Use

  • Always use Stainless Steel (SS) tubing to convey hydrogen gas.
  • Prevent hydrogen leaks by carefully connecting gas regulator and tubing.
  • Keep vigilant for leaks.
  • Can only be used in spaces with adequate ventilation.
  • Eliminate likely ignition sources.
  • Always assume hydrogen is present and verify the system has been purged to less than one percent when performing system maintenance on a hydrogen system. Inert gases such as Nitrogen & Argon can be used for purging.
  • Anaerobic chambers: Always assume oxygen is present and verify the system has been purged to the appropriate level when reintroducing hydrogen into a system.
  • Oxygen and hydrogen sensors are required at all times. No exceptions.

Oxidizing Gases

Storage

  • Do not permit oil or grease to come in contact with compressed oxidizing gases — explosions may occur!
  • Separate oxidizers from cylinders containing flammable gases by a minimum distance of 20 feet or by a noncombustible partition extending not less than 18 inches above and to the sides of the stored material and have a 2 hour fire wall rating.
  • Never store oxidizers near flammable solvents, combustible materials, unprotected electrical connections or ignition or heat sources.

Note: Fire code piping requirements may apply in your facility. Consult the Chemical Hygiene Officer and UTD Fire Marshal.

Operations

  • Diligently clean regulators and tubing used with oxidizing gases to remove oil and other reducing agents.

Piping

  • Oxygen systems must be plumbed with steel, brass, copper or stainless steel (as per National Fire Protection Association regulations).
  • Plumbing must be installed by Facilities Management.
  • Must be approved by the Chemical Hygiene Officer and UTD Fire Marshal.

Corrosive Gases

Storage

Never store corrosives longer than six months (examples: ammonia, hydrogen chloride, chlorine, and methylamine). Cylinders containing corrosives degrade over time.

Operations

  • Inspect cylinder valves periodically for corrosion.
  • If a cylinder or valve is noticeably corroded, contact the gas vendor and follow their instructions.
  • Alert the vendor to any damage that might impair the integrity of the cylinder before the cylinder is returned.
  • Use caution if flow does not immediately start when a valve is opened slightly — there could be a plug in the valve.

Toxic or High Hazard Gases

Additional precautions are required for toxic and hazardous gases (classes 4, 3, and 2).

See the Toxic and Hazardous Gas Classifications Chart to identify the hazard class of a particular gas.

See Hazard Class Requirements Matrix for detailed information on requirements and exemptions.

Handle toxic, flammable and corrosive gases in a fume hood.

See the “Flammable, oxidizing, and corrosive gases” section above for special precautions.

Caution: Avoid using lecture bottles whenever possible. Lecture bottles have universal threads and valves, and some of them are interchangeable. This increases the risk of accidentally mixing incompatible materials.

Using Helium to Fill Balloons on Campus

Helium is a colorless and odorless compressed gas. It is non-toxic and non-flammable.

If you use helium to fill balloons for parties or social events, be aware that careless handling of the cylinders or improper use of helium could cause an accident with serious results.

Follow these guidelines for safely using helium to fill balloons:

  • Follow all compressed gas guidelines described on this page. The same hazards and methods for safely transporting, storing and working with industrial CG cylinders apply to helium cylinders used to fill balloons.
  • Always use the proper equipment designed for balloon-filling operations. Order your helium and balloon valve/inflator from UTD’s preferred vendor for next-day delivery.

Follow these guidelines for balloon-filling operations:

  • Fill balloons in well-ventilated areas to prevent the risk of asphyxiation.
  • Check all connections for leaks prior to use.
  • Place balloons firmly onto the rubber nozzle and tilt. The further the nozzle is tilted, the higher the pressure that will be released.
  • Make sure the rubber nozzle is not pressing against the inside wall of the balloon neck during inflation. This can blow a hole through the balloon.
  • Close the cylinder at the valve after each use. Helium can leak through the inflator if left on for long periods of time.
  • Never leave the cylinder unattended when it’s operational.
  • Never allow anyone to breathe helium from the cylinder. Although helium is not poisonous, it can lead to asphyxiation.
  • Never allow children or unauthorized people to handle balloon-filling equipment.
  • Minimize waste by ensuring gas does not escape when the balloon is being inflated, or when the balloon is removed from the nozzle.

Transporting the Cylinder

  • Remove the inflator and place the protective cap on before transporting the cylinder to prevent damage.
  • Use a cylinder cart to transport cylinders, even for short distances. Secure the cylinder to the cart so it can’t tip, fall over or bang into another cylinder.
  • Do not roll, drag or slide cylinders.
  • Do not lift cylinders by cylinder caps.

Storing the Cylinder

  • Remove the inflator and place the protective cap on the cylinder when storing.
  • Store the cylinder upright and secure it to a substantial, fixed surface with upper and lower restraints made of non-combustible material, preferably chain and Unistrut®.
  • Make sure cylinders are not placed where they might form part of an electric circuit.
  • Return empty or unused cylinders promptly to the vendor.

Training

Make sure personnel are trained to safely handle and work with compressed gas. UTD Risk & Safety has developed an online training to help you understand the hazards associated with compressed gases. Email Risk & Safety at Safety@utdallas.edu for more information.